HKVA PWM SOLAR PCU INVERTER

GSR Power Solar Inverter provides you the optimum performance & efficiency towards solar power generation & also provides your appliance the exact replication of mains power.

Technical Specifications*

Parameters Normal Mode UPS Mode
Mains AC Lower Voltage Limit 100 +-5 VAC 180 +-5 VAC
Mains AC Lower Recovery Volt. 110 +5 VAC 190 + 5 VAC
Mains AC Higher Voltage Limit 280 +5 VAC 260 + 5 VAC
Mains AC Higher Recovery Volt. 270 +5 VAC 250 + 5 VAC
Output Voltage with full load in ECO/ Normal Mode 220 + 10 V
Battery Low Cut-Off Voltage (Settable) 10.4 + 0.2 V (per Batt.) Default
Mains 0/p Frequency Same as Input
INV. 0/p Frequency 50 + 1.0 Hz

Solar Charge Controller

Solar Charge Controller
Technology DSP based intelligent battery charging and Charge Sharing with Mains#
Charge Controller Type PWM based
Peak Solar PV Current 50/ 70 Amps
Solar Battery Charging Current (settable) 40 Amps (default)
Solar Batt. Low Cut Voltage (Settable) 11.5V (Default)
PV Reverse Polarity Protection Available
Reverse Current flow to PV Protection Available
Battery Charging
Battery Charging Volt. Range 120 to 280 V
180 to 260 V
Mains Charging Current (Settable) HC — 5-22A (range)
NC — 25% less than HC
Trickle Charging Current Limit 0.5 + 0.3A
Boost Voltage (settable) 14.4 + 0.1 V (per Batt.) (default)
Float Voltage 13.6 + 0.2 V (per Batt.)
Overload 100 + 3% (with Auto reset function
Short Circuit Protection > 300% Load (with manual reset function)
Change Over Time < 20 ms upto 2KVA
< 60 mSec 2.75 KVA and above
< 10 mSec

FEATURES

  • Interactive multicolor LCD display.
  • Solar KWH used on digital display.
  • Solar PV reverse voltage protection.
  • Advanced Pure Sine Wave Boost Technology.
  • 50 Am p. PWM built.in solar charge conlroller.
  • Smart solar selection logic based on Real Time Clock
  • Provision to maintain battery gravity for better battery performance.
  • Maximum grid current saving by charging through "Solar Power Only".
  • Maximum utilization of Solar current through monitoring of abrupt weather conditions.
  • Electronic over current charging proledion
  • Provision for setting critical parameters of solar & Battery.

Inverter Rating Available :

  • 2.5KVA, 3.6KVA, 5.2KVA, 7.5KVA, 10KVA