LKVA PWM SOLAR PCU INVERTER

GSR Power Solar Inverter provides you the optimum performance & efficiency towards solar power generation & also provides your appliance the exact replication of mains power.

AC Mains Mode

I/p Volt. Range (Normal Mode) 90 to 290 VAC ± 5 VAC
I/p Volt. Range (UPS Mode) 145 to 270 VAC ± 5 VAC
Changeover Time Maximum <=20 ms
Max. Charging Current (NC) 25% less than HC
Max. Charging Current (HC) 15A ± 1Al18A± 1A 26A± 1A 17A± 1A 20A± 1A
Boost Charging Voltage 14.4 ± 0.1 voe 28.8±0.2 voe
Float Charging Voltage 13.7 ± 0.2 voe 27.4± 0.4 voe
Stabilizer mode If input Mains AC Volt. < 180V Output will be input Mains AC Volt.+30% V.

Power Storage Backup Mode

Output Voltage at No Load 225 VAC ± 7 VAC
Output Frequency 50.0Hz ± 0.5Hz
Output Wave Form (At No Load) 100% Pure Sine Wave
Power storage Low alarm (VDC) 10.6 ± 0.2 21.2±0.2
Power storage Low protection) 10.4 ± 0.2 voe 20.8±0.2

Solar Charge Controller

Technology DSP based intelligent power storage charging and Charge Sharing with Mains#
Peak Solar PV Current 50 Amps
Solar Power storage Charging Current (settable) 40 Amps (default)
Solar Power storage Low Cut Voltage (Settable) 11.5V (Default)
PV Reverse Polarity Protection Available
Reverse Current flow to PV Protection Available

Current Boost Function Mode in Normal Mode Only

Charging Current at 1OOV AC 8A ±1A

LCD Display

Mains on, UPS on, Short Circuit, Overload, Charging, Power storage Low, Fuse Blown, MCB Trip

Protection

Power storage Low, Over Load, Power storage full Charge, Over Temperature, short circuit *As a process of continuous product improvement, the specifications are subjected

FEATURES

  • Interactive multicolor LCD display.
  • Solar KWH used on digital display.
  • Solar PV reverse voltage protection.
  • Advanced Pure Sine Wave Boost Technology.
  • 50 Am p. PWM built.in solar charge conlroller.
  • Smart solar selection logic based on Real Time Clock
  • Provision to maintain battery gravity for better battery performance.
  • Maximum grid current saving by charging through "Solar Power Only".
  • Upto 30% extra current incase of emergency through emergency current boost.
  • Electronic over current charging proledion
  • Provision for setting critical parameters of solar & Battery.
  • Maximum utilization of Solar current through monitoring of abrupt weather conditions.

AVAILABLE RANGE

  • 900VA, 1100VA, 1600VA, 2200VA